Dual Source Switch Smart Three Phase Keypad Prepaid/Prepayment Energy Meter
Click image to view full size image
Product: Views:290Dual Source Switch Smart Three Phase Keypad Prepaid/Prepayment Energy Meter 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-09-17 18:28
  Inquiry
Details


CA368 Three Phase Keypad Prepayment Electricity Meter


 Main Features
  • Energy Measurement
Total and time-sharing forward active & reactive energy measurement
Total and time-sharing reverse active & reactive energy measurement
Save last one to sixteen months energy data
  • 20 digit Standard Transfer Specification(STS)
Credit data transfered from a point of sale (POS) or vending system is made into a numeric token in a 20 digit number using the Standard Transfer Specification (STS) encryption techniques, which comply with IEC62055 protocol 

* Post-prepaid and Prepaid switch Function

Measure Two sources of electricity energy, one is GRID which is post-paid function,

another is Diesel Generator which is prepaid function, and the meter and switch automaticly.

  • Load control function
When the residual energy is 0 or the allowable overdraft that both sides agreed, this meter will send out power-off signal to have load switch cut off power. The power will be recovered automatically after inputting new purchased energy amount.
  • Programmable low credit warning
The meter can be programmed for setting user credit warning threshold, When the meter's residual energy is equal to credit warning threshold, the meter will start the audio & video warning function in a way of warning light flashing
  • Tamper detection
With event recording function (including cover-opening event, tamper event and power failure event)
  • Max. Demand Measurement
Measure total and time-sharing forward active & reactive maximum demand and time of occurred
Measure total and time-sharing reverse active & reactive maximum demand and time of occurred
Measure total forward & reverse apparent maximum demand and time of occurred
  • Real Time Measurement
Real-time measurement of the phase voltage, current, total active power, reactive power, apparent power, total power factor, power grid frequency
  • TOU
4tariffs, 100holidays, 14seasontables, 8time zonetables, each table on maximum 14 time zones
  • Event Log
The last 10 records of following events:Power-down, Programing, Cover opening, Terminal cover opening, Reverse power, Phase Fail.the records include data and time
  • Optical port interface
Communication standards DL/T645-2007, 1200bps for communication
Support IEC62056-21 protocol
  • RS-485 serial interface
Communication standards DL/T645-2007, 2400bps for communication
Support IEC62056(DLMS/COSEM) protocol
  • LCD display
Number of digits value field Up to 8
Digit size 6x14.5mm
  • Communication modules(optional)
GPRS module:EGSM900/DCS1800 dual-band,support GSM/GPRS phase2/2+ protocol
PLC module: according to Technology Standards of SSC163X ,center frequency 270K, FSK modulate technolgy

Technical parameters:
Electrical parameters:
Voltage
Nominal voltage Un 3x220V
Extended operating voltage range 80%~115%Un
Limited voltage 70%~120%Un
Frequency  
Nominal frequency fn 60Hz
tolerance 5%
Current  
Basic current(Ib) 10A
Maximum current(Imax) 100A
Starting current(Ist) 30mA
Active energy constant 400imp/kWh
Measurement Accuracy  
Active energy to IEC6205321 Class1.0
Reactive energy to IEC6205323 Class2.0
Power Consumption  
Power consumption in Voltage circuit <2W <8VA
Power consumption in current circuit <1VA
Temperature range  
Operation meter 25ºC to+70ºC
Storage 40ºC to+85ºC
 
Insulation strength
AC Insulation strength 4kV at 50Hz during 1min
Impulse voltage 1.2/50μs mains connections 8kV
   
Electro Magnetic Compatibility
Electrostatic discharges  
Contact discharge 8kV
Air discharge 16kV
Electromagnetic RF fields  
27MHz to 500MHz typical 10V/m
100kHz to 1GHz typical 30V/m
Fast transient burst test 4kV
   
Mechanical requirements  
Meter shell Protection Rate IP54
Protection classII

Installation Dimension Figure